56 Chapter 2 Configuring and graphing the switch
214393-A
Table 19 describes the SNMP Info tab fields.
Trap Receivers tab
The Trap Receivers tab lists the devices that will receive SNMP traps from the
BayStack 380-24F switch.
To open the Trap Receivers tab:
1 Select the chassis.
2 From the shortcut menu, choose Edit > Chassis.
The Chassis dialog box opens (Figure 22 on page 50) with the System tab
displayed.
3 Click the Trap Receivers tab.
The Trap Receivers tab opens (Figure 26).
Figure 26 Trap Receivers tab
Table 19 SNMP tab fields
Field Description
LastUnauthenticatedIpAddress The last IP address that was not authenticated
by the device.
LastUnauthenticatedCommunityString The last community string that was not
authenticated by the device.
TrpRcvrMaxEnt The maximum number of trap receiver entries.
TrpRcvrCurEnt The current number of trap receiver entries.
TrpRcvrNext The next trap receiver entry to be created.