Install NTMF94EA and NTCW84KA cables 197
Figure 36
NTCW84KA ELAN, TLAN, DCH, and serial cable
Install the NTMF94EA cable (for non-DCHIP cards)
Follow the steps in Procedure 10 "Installing the NTMF94EA cable" (page
197) to install the NTMF94EA cable for non-DCHIP cards.
Procedure 10
Installing the NTMF94EA cable
Step Action
1
Connect the NTMF94EA cable (see Figure 37 "NTMF94EA ELAN,
TLAN and serial port cable" (page 198)) to the I/O panel connector.
Make sure to connect to the I/O panel connector which corresponds
to the left slot number of the DCHIP card.
2
Secure the mounting screw provided on the top of the Shielded
25-Pair Amphenol Connector to the I/O Panel filter connector in
order to tie the shield of the LAN cable to the frame ground for EMC
compliance.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 01.01 Standard
Release 5.0 30 May 2007
Copyright © 2007, Nortel Networks
.