Operation 49
Figure 11
Typical IPE trunk card architecture
The switch communicates with IPE modules over two separate interfaces.
Voice and signaling data are sent and received over DS-30X loops and
maintenance data is sent over a separate asynchronous communication
link called the card LAN link.
Signaling data is information directly related to the operation of the
telephone line. Some examples of signaling commands are as follows:
off hook/on hook
ringing signal on/off
message waiting lamp on/off
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.