Nortel Networks BCM200 Uživatelský manuál Strana 169

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 382
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 168
Chapter 11 Installing the analog terminal adapter 169
BCM200/400 4.0 Installation and Maintenance Guide
Figure 82 ATA2 top view
Figure 83 shows the pin-outs for the connection cables.
Figure 83 ATA2 pin-outs
To connect the ATA2
1 Connect one end of a line cord to the ATA2 terminal jack.
2 Connect the other end to your telephone, modem, or fax machine.
3 Connect one end of a line cord to the ATA2 line jack.
4 Connect the other end to an available station port on the BCM main unit or expansion unit.
5 For a 120 V or 230 V system, plug the DIN connector of the power supply cord into the power
supply connector receptacle. Plug the adapter into a standard AC outlet.
Mounting the ATA2
After the ATA2 is correctly connected, you can mount the unit on a wall, as described in this
section.
Caution: In North America, the ATA2 must be powered from a Class 2 power source that
is UL- and CSA-approved.
In Europe, the ATA2 must be powered from a Class II power source that is CE marked.
=
24 V ~
0.006 A
Terminal jackLine jack Power supply connector receptacle
TCM*
TCM*
Ring (B-Lead)
Tip (A-Lead)
Line jack
Terminal jack
* The TCM input is not polarity sensitive.
Zobrazit stránku 168
1 2 ... 164 165 166 167 168 169 170 171 172 173 174 ... 381 382

Komentáře k této Příručce

Žádné komentáře