Nortel Networks Server 1005r Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Části počítačových skříní Nortel Networks Server 1005r. Nortel Networks Server 1005r User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 206
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Release 4.0

CallPilotRelease 4.0Document Number: 555-7101-512Document Version: Standard 1.10June 20071005r Server Maintenance and Diagnostics

Strany 2 - Trademarks

Task List Standard 1.0810 CallPilotTo replace the DVD combo drive ... 127To replace the DIMM cards ...

Strany 3

Using CallPilot system utilities Standard 1.10100 CallPilotFigure 13: Channel Monitor with M1CallPilot servicesThe Service Name pane shows the status

Strany 4 - Information for Japan

June 2007 Using CallPilot system utilities1005r Server Maintenance and Diagnostics 101The critical services that are required for basic CallPilot call

Strany 5

Using CallPilot system utilities Standard 1.10102 CallPilotYour 1005r server has either one or three MPB96 boards. Each MPB96 board has 12 DSP section

Strany 6 - 6 CallPilot

June 2007 Using CallPilot system utilities1005r Server Maintenance and Diagnostics 103Figure 14: System Info tabThe numbered items provide information

Strany 7 - Publication history

Using CallPilot system utilities Standard 1.10104 CallPilotFigure 15: Legend/Help tab

Strany 8 - 8 CallPilot

1005r Server Maintenance and Diagnostics 105Chapter 8Replacing basic chassis componentsIn this chapterRemoving and replacing the front bezel 106Removi

Strany 9 - Task List

Replacing basic chassis components Standard 1.10106 CallPilotRemoving and replacing the front bezelRemove the front bezel to service the hard drives a

Strany 10 - 10 CallPilot

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 1071 Loosen the captive screws (A) on both sides of the front bez

Strany 11 - Contents

Replacing basic chassis components Standard 1.10108 CallPilotRemoving and replacing the server coverRemove the server cover if you must service the in

Strany 12 - 9 RAID operations 137

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 109Figure 17: Server cover5 Lift the cover straight up to remove

Strany 13 - Index 197

1005r Server Maintenance and Diagnostics 11Contents1 How to get Help 152 Outlining maintenance and diagnostics activities 171005r server features. . .

Strany 14 - 14 CallPilot

Replacing basic chassis components Standard 1.10110 CallPilotRemoving and replacing the processor air ductYou must remove the air duct to access the p

Strany 15 - How to get Help

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 111Figure 18: Processor air duct5 Lift the air duct from the serv

Strany 16 - 16 CallPilot

Replacing basic chassis components Standard 1.10112 CallPilotReplacing the power supplyThe power supplies are hot-swappable and you can replace each p

Strany 17 - Outlining maintenance and

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 1131 Depress and hold the green lever (A) to disengage the power

Strany 18 - 1005r server features

Replacing basic chassis components Standard 1.10114 CallPilotReplacing a hard driveTwo hot-swappable SCSI drives are installed in your chassis. You do

Strany 19

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 115Figure 20: Front panel  Hard drive 0 is on the right (T). The

Strany 20 - 20 CallPilot

Replacing basic chassis components Standard 1.10116 CallPilotFigure 21: SCSI hard drive carrier5 Pivot the latch (A) into the upright position.6 Pull

Strany 21

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 117Figure 22: Hard disk drive location in carrier10 With the blac

Strany 22 - 22 CallPilot

Replacing basic chassis components Standard 1.10118 CallPilotReplacing the four-fan assemblyThe four-fan cooling assembly is not hot-swappable. You mu

Strany 23 - Replacement parts

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 119Figure 23: Cooling fan assembly6 Loosen the captive screw (B)

Strany 24 - Reference documents

Contents Standard 1.1012 CallPilotViewing component states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Starting and s

Strany 25 - Chapter 3

Replacing basic chassis components Standard 1.10120 CallPilotReplacing the dual NIC cardYour server has three low-profile PCI add-in cards. The RAID c

Strany 26 - Startup diagnostics overview

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 121Requirements Phillips (cross head) screwdriver, #1 and #2 bit

Strany 27 - Basic hardware check

Replacing basic chassis components Standard 1.10122 CallPilotFigure 24: DS30X cables for high capacityNote: If you have the high capacity configuratio

Strany 28 - Table 1: Alarm fault LEDs

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 123Figure 25: SCSI cable attached to RAID card7 Lift the blue tab

Strany 29

Replacing basic chassis components Standard 1.10124 CallPilotFigure 26: PCI riser card assembly8 Turn the riser card upside down and place it on a tab

Strany 30 - To run the POST

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 125Figure 27: Low-riser PCI card9 Release the retention bar (A).1

Strany 31 - Table 2: POST beep codes

Replacing basic chassis components Standard 1.10126 CallPilotFigure 28: PCI riser assembly power cord14 Hold the PCI riser assembly by the two blue ha

Strany 32 - Table 3: BIOS error messages

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 127Figure 29: PCI riser assembly rear grooves16 Reconnect the PCI

Strany 33 - Error message Description

Replacing basic chassis components Standard 1.10128 CallPilotResult: The board replacement is complete. 25 Test the system to ensure the new board is

Strany 34

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 129Replacing the DVD combo driveThe DVD combo drive is not hot-sw

Strany 35

June 2007 Contents1005r Server Maintenance and Diagnostics 13Locating the voice processing boards. . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 36 - 36 CallPilot

Replacing basic chassis components Standard 1.10130 CallPilotFigure 30: DVD combo drive assembly6 Slide the DVD combo drive assembly from the chassis.

Strany 37

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 131b. Screw the carrier shut with the three screws.c. Reconnect t

Strany 38 - Interpreting hard drive LEDs

Replacing basic chassis components Standard 1.10132 CallPilotReplacing memory DIMMsFour Dual Inline Memory Modules (DIMMs) are installed on your serve

Strany 39

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 133Figure 31: Memory DIMM locations6 Push the clips at each end o

Strany 40 - 40 CallPilot

Replacing basic chassis components Standard 1.10134 CallPilot11 Push down on the top edge of the DIMM until the retaining clips snap into place. The r

Strany 41 - Chapter 4

June 2007 Replacing basic chassis components1005r Server Maintenance and Diagnostics 135Replacing the software feature keyIf you upgrade your system o

Strany 42 - Overview

Replacing basic chassis components Standard 1.10136 CallPilotFigure 33: Inserting the feature key

Strany 43 - Viewing event logs

1005r Server Maintenance and Diagnostics 137Chapter 9RAID operationsIn this chapterOutlining RAID functions 138Verifying the RAID firmware 139Configur

Strany 44 - Types of Windows event logs

RAID operations Standard 1.10138 CallPilotOutlining RAID functionsRedundant Array of Independent Disks (RAID) is a technology that can combine two or

Strany 45 - Figure 4: Event Viewer

June 2007 RAID operations1005r Server Maintenance and Diagnostics 139Verifying the RAID firmwareYou require the following minimum RAID firmware versio

Strany 46 - Figure 5: Application log

Contents Standard 1.1014 CallPilot

Strany 47 - Figure 6: System log

RAID operations Standard 1.10140 CallPilotIf the firmware is not correct, perform a firmware update. For instructions, see “To upgrade or downgrade th

Strany 48 - Using TCP/IP diagnostic tools

June 2007 RAID operations1005r Server Maintenance and Diagnostics 1412.1005r server FRU/SDR firmware update3.1005r server Board Management Controller

Strany 49

RAID operations Standard 1.10142 CallPilotConfiguring RAID using LSI320-1 controller and Ctrl+MThe configuration of the RAID card is stored on both th

Strany 50 - The ping command

June 2007 RAID operations1005r Server Maintenance and Diagnostics 1433 From the Objects menu, select Adapter and press Enter.4 From the Adapter menu,

Strany 51 - The tracert command

RAID operations Standard 1.10144 CallPilotResult: The display changes to ONLIN A01-01. 11 Select A01-02 and press the Spacebar. Note: The drives blink

Strany 52 - Table 6: Tracert parameters

June 2007 RAID operations1005r Server Maintenance and Diagnostics 145Verifying consistency on the drivesThis optional consistency check on the logical

Strany 53 - The arp command

RAID operations Standard 1.10146 CallPilotResult: An end of session message appears.5 Click OK.

Strany 54 - The nbtstat command

June 2007 RAID operations1005r Server Maintenance and Diagnostics 147RAID splittingEnsure that your system is in full working order and the RAID hardw

Strany 55 - Parameter Description

RAID operations Standard 1.10148 CallPilotAt this point, the RAID is split, and the drive marked FAILED is the backup drive and is no longer written t

Strany 56 - 56 CallPilot

June 2007 RAID operations1005r Server Maintenance and Diagnostics 149To synchronize the RAID after a successful PEP installationTo restore RAID to ful

Strany 57 - The netstat command

1005r Server Maintenance and Diagnostics 15Chapter 1How to get HelpThis chapter explains how to get help for Nortel products and services.Getting Help

Strany 58 - Using the chkdsk utility

RAID operations Standard 1.10150 CallPilot1 Restart the server and enter the Ctrl+M utility when prompted during system bootup.2 From the Management m

Strany 59

June 2007 RAID operations1005r Server Maintenance and Diagnostics 151Replacing the RAID cardThe RAID card is in low-profile slot 1 (counting from the

Strany 60 - 60 CallPilot

RAID operations Standard 1.10152 CallPilotRequirements Phillips (cross head) screwdriver, #1 and #2 bit RAID card replacement kit electrostatic dis

Strany 61 - Monitoring server hardware

June 2007 RAID operations1005r Server Maintenance and Diagnostics 153Figure 35: DS30X cables for high capacityNote: If you have the high capacity conf

Strany 62 - ISM overview

RAID operations Standard 1.10154 CallPilotFigure 36: SCSI cable to RAID card7 Lift the blue tabs and pull up on the riser to remove the riser card ass

Strany 63 - Chapter 6

June 2007 RAID operations1005r Server Maintenance and Diagnostics 155Figure 37: PCI riser card assembly8 Turn the riser card upside down and place it

Strany 64 - Component dependencies

RAID operations Standard 1.10156 CallPilotFigure 38: Low-riser PCI card9 Release the retention bar (A).10 Replace the card (B).11 Lock the retention b

Strany 65 - Detecting hardware problems

June 2007 RAID operations1005r Server Maintenance and Diagnostics 157Figure 39: PCI riser assembly power cord14 Reconnect the DS30X cable or cables to

Strany 66 - Alarm Monitor

RAID operations Standard 1.10158 CallPilotFigure 40: PCI riser assembly rear grooves17 Reconnect the PCI riser assembly power cord.18 Reconnect the SC

Strany 67

June 2007 RAID operations1005r Server Maintenance and Diagnostics 15926 Configure the new RAID card. Refer to “To configure an LSI320-1 RAID system” o

Strany 68 - Event Browser

How to get Help Standard 1.1016 CallPilotwww.nortel.com/callusGetting Help from a specialist by using an Express Routing Code To access some Nortel Te

Strany 69

RAID operations Standard 1.10160 CallPilot

Strany 70 - Disabling call channels

1005r Server Maintenance and Diagnostics 161Chapter 10Replacing or adding voice processing boardsIn this chapterM1/CS1000 switch connectivity 162Locat

Strany 71 - The Maintenance screen

Replacing or adding voice processing boards Standard 1.10162 CallPilotM1/CS1000 switch connectivityThere are two valid configurations for MPB96 boards

Strany 72 - 72 CallPilot

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 163Locating the voice processing boardsFigure 41 on page

Strany 73 - Table 11: Component sections

Replacing or adding voice processing boards Standard 1.10164 CallPilotDSP numbering and locationDSPs are the built-in voice processing components on M

Strany 74 - 74 CallPilot

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 165Replacing an MPB96 boardThis section describes how to

Strany 75 - Viewing component states

Replacing or adding voice processing boards Standard 1.10166 CallPilotMPB96 boards are not hot-swappable and you must power down the system before rep

Strany 76 - Alert icons

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 1676 Disconnect the DS30X cable from the MPB96 card in t

Strany 77

Replacing or adding voice processing boards Standard 1.10168 CallPilotFigure 44: SCSI cable attached to RAID card8 Lift the blue tabs and pull up on t

Strany 78

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 169Figure 45: PCI riser card assembly9 Turn the riser ca

Strany 79 - Stop versus courtesy stop

1005r Server Maintenance and Diagnostics 17Chapter 2Outlining maintenance and diagnostics activitiesIn this chapter1005r server features 18Maintenance

Strany 80 - To start or stop a component

Replacing or adding voice processing boards Standard 1.10170 CallPilotFigure 46: CT bus cable attached to MPB96 boards.11 Release the retention clip b

Strany 81 - Button Description

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 171Figure 47: Full-height PCI card12 Remove the rear ret

Strany 82 - Before you begin

Replacing or adding voice processing boards Standard 1.10172 CallPilotFigure 48: Full-size PCI riser card red power cable17 Arrange the PCI riser asse

Strany 83 - To run a diagnostic test

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 17318 Line up the two grooves on the back lip of the PCI

Strany 84 - 84 CallPilot

Replacing or adding voice processing boards Standard 1.10174 CallPilotResult: The Windows New Hardware Found Wizard screen appears.24 Click Next.25 Se

Strany 85 -  diagnostic title

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 175Upgrading to high capacityThis section describes how

Strany 86 - 86 CallPilot

Replacing or adding voice processing boards Standard 1.10176 CallPilot3 Attach the ESD strap to your wrist and attach the other end to a known grounde

Strany 87

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 177Figure 52: PCI riser card assembly9 Turn the riser ca

Strany 88 - 88 CallPilot

Replacing or adding voice processing boards Standard 1.10178 CallPilotFigure 53: Full-height PCI card13 Connect the 3-drop CT bus cable to the MPB96 c

Strany 89

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 179Figure 54: CT bus cable attached to MPB96 boards14 Tu

Strany 90 - 90 CallPilot

Outlining maintenance and diagnostics activities Standard 1.1018 CallPilot1005r server featuresNote: To comply with the EU (European Union) RoHS direc

Strany 91 - Chapter 7

Replacing or adding voice processing boards Standard 1.10180 CallPilotFigure 56: PCI riser assembly power cable17 Line up the two grooves on the back

Strany 92

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 181Figure 57: PCI riser assembly alignment studs and slo

Strany 93 - Diagnostics Tool

Replacing or adding voice processing boards Standard 1.10182 CallPilotFigure 58: DS30X cables for high capacity22 Replace the chassis cover.23 Take th

Strany 94 - 94 CallPilot

June 2007 Replacing or adding voice processing boards1005r Server Maintenance and Diagnostics 183Result: The high capacity expansion is complete. 31 T

Strany 95 - PEP Maintenance utility

Replacing or adding voice processing boards Standard 1.10184 CallPilot

Strany 96 - Session Trace

1005r Server Maintenance and Diagnostics 185Chapter 11Maintaining the BIOS and system board firmwareIn this chapterConfiguring the 1005r BIOS and firm

Strany 97 - To find a session

Maintaining the BIOS and system board firmware Standard 1.10186 CallPilotConfiguring the 1005r BIOS and firmwareThe Basic Input/Output System (BIOS) o

Strany 98 - 98 CallPilot

June 2007 Maintaining the BIOS and system board firmware1005r Server Maintenance and Diagnostics 187When to upgrade the BIOSThe CallPilot server is sh

Strany 99 - CallPilot System Monitor

Maintaining the BIOS and system board firmware Standard 1.10188 CallPilotResult: The server boots from the DVD and the Startup Menu appears.1.Install

Strany 100 - 100 CallPilot

June 2007 Maintaining the BIOS and system board firmware1005r Server Maintenance and Diagnostics 189Result: The system reboots and the Startup Menu ap

Strany 101 - Windows Control Panel

June 2007 Outlining maintenance and diagnostics activities1005r Server Maintenance and Diagnostics 19Figure 1: Front panel controlsLabel Control or fe

Strany 102 - System Info tab

Maintaining the BIOS and system board firmware Standard 1.10190 CallPilotBIOS settingsTable 15 on page 190 displays the 1005r server BIOS settings. As

Strany 103 - Legend/Help tab

June 2007 Maintaining the BIOS and system board firmware1005r Server Maintenance and Diagnostics 191USB Configuration USB Function: EnabledLegacy USB

Strany 104 - Figure 15: Legend/Help tab

Maintaining the BIOS and system board firmware Standard 1.10192 CallPilotSecurity All Features DisabledServer This is a view only menuSerial Power Con

Strany 105 - Replacing basic chassis

June 2007 Maintaining the BIOS and system board firmware1005r Server Maintenance and Diagnostics 193Using system event logsThe system event logs recor

Strany 106 - To remove the front bezel

Maintaining the BIOS and system board firmware Standard 1.10194 CallPilot6 Choose Run SEL Viewer Utility and click Continue.Result: The SEL Viewer scr

Strany 107 - To replace the front bezel

June 2007 Maintaining the BIOS and system board firmware1005r Server Maintenance and Diagnostics 195If you do not have the image DVD, you can clear th

Strany 108 - To remove the server cover

Maintaining the BIOS and system board firmware Standard 1.10196 CallPilotMaintaining the onboard video and network cardsNetwork card failureThe networ

Strany 109 - To replace the server cover

1005r Server Maintenance and Diagnostics 197IndexAalarm boardreplacement of 132Alarm Monitor 66alarmsabout 64, 66investigating 66alert icons, componen

Strany 110 - Requirements

Index Standard 1.10198 CallPilotcall, working with 89–90disabling 70multimedia, working with 87–88chkdsk utility 58parameters and descriptions 58runni

Strany 111 - Figure 18: Processor air duct

June 2007 Index1005r Server Maintenance and Diagnostics 199tracert 51Diagnostics section, Maintenance screen 73Diagnostics Tool 92diagnostics toolTCP/

Strany 112 - Replacing the power supply

Standard 1.102 CallPilotCopyright © 2007 Nortel Networks.All Rights Reserved.The information in this document is subject to change without notice. The

Strany 113 - Figure 19: Power supplies

Outlining maintenance and diagnostics activities Standard 1.1020 CallPilotBack panel controls and featuresThe following diagram shows the back panel c

Strany 114 - Replacing a hard drive

Index Standard 1.10200 CallPilotIindicators 196integrated diagnosticsrunning 83–84troubleshooting failures 83when to run 82ipconfig command 48flags an

Strany 115 - Figure 20: Front panel

June 2007 Index1005r Server Maintenance and Diagnostics 201Nnbtstat command 54parameters and descriptions 55running from Windows 56syntax 54netstat co

Strany 116 - 116 CallPilot

Index Standard 1.10202 CallPilotserver cover 108removal of 108Session Trace utility 96startup problemswhat to do 36Stop, description 79system event lo

Strany 117

June 2007 Index1005r Server Maintenance and Diagnostics 203Vvideo card, failure 196viewing 45WWindowsviewing 45

Strany 118 - 118 CallPilot

Index Standard 1.10204 CallPilot

Strany 120 - Replacing the dual NIC card

1005r Server Maintenance and DiagnosticsCallPilotRelease 4.0Document Number: 555-7101-512Document Version: Standard 1.10June 2007Copyright © 2007 Nort

Strany 121 - To replace a dual NIC card

June 2007 Outlining maintenance and diagnostics activities1005r Server Maintenance and Diagnostics 21B PCI low-profile card brackets. Numbered (1, 2,

Strany 122 - 122 CallPilot

Outlining maintenance and diagnostics activities Standard 1.1022 CallPilotMaintenance and diagnostics overviewThe maintenance and diagnostic activitie

Strany 123

June 2007 Outlining maintenance and diagnostics activities1005r Server Maintenance and Diagnostics 23Replacement partsBefore replacing any parts on yo

Strany 124 - 124 CallPilot

Outlining maintenance and diagnostics activities Standard 1.1024 CallPilotReference documentsFundamentalsCallPilot Fundamentals Guide (555-7101-010)Pl

Strany 125 - Figure 27: Low-riser PCI card

1005r Server Maintenance and Diagnostics 25Chapter 3Troubleshooting your CallPilot systemIn this chapterStartup diagnostics overview 26Basic hardware

Strany 126 - ATTENTION

Troubleshooting your CallPilot system Standard 1.1026 CallPilotStartup diagnostics overviewThis section contains procedures for interpreting the start

Strany 127

June 2007 Troubleshooting your CallPilot system1005r Server Maintenance and Diagnostics 27Basic hardware checkThis section describes some basic checks

Strany 128 - 128 CallPilot

Troubleshooting your CallPilot system Standard 1.1028 CallPilota couple of seconds. When the AC power is removed from one power supply, it’s LED turns

Strany 129 - Replacing the DVD combo drive

June 2007 Troubleshooting your CallPilot system1005r Server Maintenance and Diagnostics 29For more information about POST, see “Power-On Self-Test dia

Strany 130 - 130 CallPilot

June 20071005r Server Maintenance and Diagnostics 3CRYSTAL REPORTS is a trademark of Seagate Software Inc.EUDORA is a trademark of Qualcomm.eTrust and

Strany 131

Troubleshooting your CallPilot system Standard 1.1030 CallPilotPower-On Self-Test diagnosticsThe Power-On Self-Test (POST) is a system diagnostic prog

Strany 132 - Replacing memory DIMMs

June 2007 Troubleshooting your CallPilot system1005r Server Maintenance and Diagnostics 31POST beep codesIf an error occurs before video initializatio

Strany 133

Troubleshooting your CallPilot system Standard 1.1032 CallPilotInterpreting BIOS error messagesWhen a recoverable error occurs during the POST, an err

Strany 134 - 134 CallPilot

June 2007 Troubleshooting your CallPilot system1005r Server Maintenance and Diagnostics 33A: Drive Error No response from the disk drive.CMOS Battery

Strany 135

Troubleshooting your CallPilot system Standard 1.1034 CallPilotUpdate OK! The NVRAM is invalid and has been updated.Updated Failed The NVRAM is invali

Strany 136 - 136 CallPilot

June 2007 Troubleshooting your CallPilot system1005r Server Maintenance and Diagnostics 35Parity Error A parity error occurred in onboard memory at an

Strany 137 - RAID operations

Troubleshooting your CallPilot system Standard 1.1036 CallPilotWhat to do when the server fails to boot into serviceThis section suggests tasks you ca

Strany 138 - Outlining RAID functions

June 2007 Troubleshooting your CallPilot system1005r Server Maintenance and Diagnostics 375 Refer to the Troubleshooting Guide (555-7101-501) for othe

Strany 139 - Verifying the RAID firmware

Troubleshooting your CallPilot system Standard 1.1038 CallPilotInterpreting hard drive LEDsRefer to L and M in Figure 3 on page 27 for the location of

Strany 140 - 140 CallPilot

June 2007 Troubleshooting your CallPilot system1005r Server Maintenance and Diagnostics 39Performing a hardware shutdownIf you cannot shut the server

Strany 141 - June 2007 RAID operations

Standard 1.104 CallPilotWINZIP is a trademark of Nico Mark Computing, Inc.XEON is a trademark of Intel, Inc.All other trademarks and registered tradem

Strany 142 - 142 CallPilot

Troubleshooting your CallPilot system Standard 1.1040 CallPilot

Strany 143 - ➝ Adapter, and then

1005r Server Maintenance and Diagnostics 41Chapter 4Using Windows online diagnostic toolsIn this chapterOverview 42Viewing event logs 43Using TCP/IP d

Strany 144 - 144 CallPilot

Using Windows online diagnostic tools Standard 1.1042 CallPilotOverviewThis section describes how to access the run-time online diagnostic tools provi

Strany 145

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 43Viewing event logsIf one or more messages appear on the moni

Strany 146 - 5 Click OK

Using Windows online diagnostic tools Standard 1.1044 CallPilotTypes of Windows event logsThree types of event logs are available from the Windows Eve

Strany 147 - RAID splitting

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 45To use the operating system Event Viewer1 Click Start > P

Strany 148

Using Windows online diagnostic tools Standard 1.1046 CallPilot2 To view a log, click the name of the log in the left pane of the window.The following

Strany 149 - PEP installation

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 47Figure 6: System log Note: The Security log, which is availa

Strany 150 - 150 CallPilot

Using Windows online diagnostic tools Standard 1.1048 CallPilotUsing TCP/IP diagnostic toolsThis section describes the following TCP/IP diagnostic too

Strany 151 - Replacing the RAID card

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 49ipconfig command syntaxThe ipconfig command uses the followi

Strany 152 - To replace the RAID card

June 20071005r Server Maintenance and Diagnostics 5       This is a Class A product based on the standard of t

Strany 153

Using Windows online diagnostic tools Standard 1.1050 CallPilotThe ping commandThe ping command sends an echo request to a specified host. Use this co

Strany 154 - 154 CallPilot

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 51To run the ping command from Windows1 Click Start > Progr

Strany 155

Using Windows online diagnostic tools Standard 1.1052 CallPilotTracert syntaxThe tracert command uses the following syntax:tracert [-d] [-h maximum_ho

Strany 156 - Figure 38: Low-riser PCI card

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 53Result: The system runs the tracert utility.4 Type Exit to e

Strany 157

Using Windows online diagnostic tools Standard 1.1054 CallPilotTo run the arp command from Windows1 Click Start > Programs > Accessories > Co

Strany 158 - 158 CallPilot

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 55nbstat command parametersTable 8: nbstat command parametersP

Strany 159 - RAID system” on page 142

Using Windows online diagnostic tools Standard 1.1056 CallPilotTo run the nbtstat command from Windows1 Click Start > Programs > Accessories >

Strany 160 - 160 CallPilot

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 57The netstat commandThe netstat command displays current TCP/

Strany 161 - Replacing or adding voice

Using Windows online diagnostic tools Standard 1.1058 CallPilotUsing the chkdsk utilityThe chkdsk utility checks a specified disk on the server and di

Strany 162 - M1/CS1000 switch connectivity

June 2007 Using Windows online diagnostic tools1005r Server Maintenance and Diagnostics 59To run the chkdsk utility from Windows1 Click Start > Pro

Strany 163

Standard 1.106 CallPilot

Strany 164 - DSP numbering and location

Using Windows online diagnostic tools Standard 1.1060 CallPilot

Strany 165 - Replacing an MPB96 board

1005r Server Maintenance and Diagnostics 61Chapter 5Monitoring server hardwareIn this chapterISM overview 62

Strany 166 - To replace an MPB96 board

Monitoring server hardware Standard 1.1062 CallPilotISM overviewIntel Server Manager (ISM) is a server management tool installed on your 1005r server.

Strany 167

1005r Server Maintenance and Diagnostics 63Chapter 6Monitoring multimedia hardwareIn this chapterUnderstanding fault management 64Alarm Monitor 66Even

Strany 168 - 168 CallPilot

Monitoring multimedia hardware Standard 1.1064 CallPilotUnderstanding fault managementFault management is a subsystem within CallPilot that detects an

Strany 169

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 65Note: The components in your system are based on your CallPilot ser

Strany 170 - 170 CallPilot

Monitoring multimedia hardware Standard 1.1066 CallPilotAlarm MonitorUse the Alarm Monitor to investigate one or more raised alarms.About alarmsAlarms

Strany 171

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 67Result: The Alarm Monitor screen appears.Figure 7: Alarm monitor sc

Strany 172 - 172 CallPilot

Monitoring multimedia hardware Standard 1.1068 CallPilotEvent BrowserUse the Event Browser to investigate a series of events that occurred around the

Strany 173

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 69Result: The Event Browser screen appears.Figure 8: Event Browser sc

Strany 174 - 174 CallPilot

1005r Server Maintenance and Diagnostics 7Publication historyJune 2007CallPilot 4.0, Standard 1.10 of the 1005r Server Maintenance and Diagnostics gui

Strany 175 - Upgrading to high capacity

Monitoring multimedia hardware Standard 1.1070 CallPilotChannel and Multimedia MonitorsThe Channel Monitor shows the status of call channels. The call

Strany 176 - 176 CallPilot

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 71The Maintenance screenUse the Maintenance screen in CallPilot Manag

Strany 177

Monitoring multimedia hardware Standard 1.1072 CallPilotFigure 9: Partially expanded tree for 1005rWhen you click a component, the screen refreshes to

Strany 178 - 178 CallPilot

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 73Table 11: Component sectionsSection DescriptionGeneral This section

Strany 179

Monitoring multimedia hardware Standard 1.1074 CallPilotMaintenance activities for each componentThe following table identifies the maintenance activi

Strany 180 - 180 CallPilot

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 75Viewing component statesView a component state to determine the gen

Strany 181

Monitoring multimedia hardware Standard 1.1076 CallPilotAlert iconsIf one of the following icons appears next to a component in the tree, then the com

Strany 182 - 182 CallPilot

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 77To view the state of a hardware component 1 Run CallPilot Manager a

Strany 183

Monitoring multimedia hardware Standard 1.1078 CallPilotStarting and stopping componentsWhen you stop a component, you take it out of service and prev

Strany 184 - 184 CallPilot

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 79Stop versus courtesy stopThe following two methods of taking a comp

Strany 185 - Chapter 11

8 CallPilotPublication history Standard 1.10

Strany 186 - 186 CallPilot

Monitoring multimedia hardware Standard 1.1080 CallPilotTo start or stop a component1 Run CallPilot Manager and log on.2 In CallPilot Manager, click M

Strany 187 - When to reconfigure the BIOS

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 81Result: The Maintenance screen refreshes to show details about the

Strany 188 - 188 CallPilot

Monitoring multimedia hardware Standard 1.1082 CallPilotRunning integrated diagnosticsRun diagnostic tests from the Diagnostics section on the Mainten

Strany 189

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 83Diagnostic tests available for each componentThe diagnostic tests t

Strany 190 - BIOS settings

Monitoring multimedia hardware Standard 1.1084 CallPilot1 Run CallPilot Manager and log on.2 In CallPilot Manager, click Maintenance > Maintenance

Strany 191 - MIRRORING

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 85Viewing the last diagnostics resultYou can review the results of di

Strany 192

Monitoring multimedia hardware Standard 1.1086 CallPilot diagnostic result: pass or fail the date and time the test was completed

Strany 193 - Using system event logs

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 87Working with the Multimedia MonitorThe Multimedia Monitor shows the

Strany 194 - To clear system event logs

Monitoring multimedia hardware Standard 1.1088 CallPilot3 Do one of the following:4 Click Courtesy Stop or Start as required.Result: If you click Cour

Strany 195

June 2007 Monitoring multimedia hardware1005r Server Maintenance and Diagnostics 89Working with the Channel MonitorThe Channel Monitor shows the statu

Strany 196 - Video card failure

1005r Server Maintenance and Diagnostics 9Task ListTo run the startup test ... 27To

Strany 197

Monitoring multimedia hardware Standard 1.1090 CallPilot3 Do one of the following:4 Click Courtesy Stop or Start as required.Result: If you click Cour

Strany 198

1005r Server Maintenance and Diagnostics 91Chapter 7Using CallPilot system utilitiesIn this chapterOverview 92Diagnostics Tool 93PEP Maintenance utili

Strany 199

Using CallPilot system utilities Standard 1.1092 CallPilotOverviewThe following table lists the CallPilot system utilities.Accessing the system utilit

Strany 200

June 2007 Using CallPilot system utilities1005r Server Maintenance and Diagnostics 93Diagnostics ToolUse the Diagnostics Tool to enable or disable Cal

Strany 201

Using CallPilot system utilities Standard 1.1094 CallPilotOn the Diagnostics Tool dialog box, select Configuration > Maintenance Startup Diag >

Strany 202

June 2007 Using CallPilot system utilities1005r Server Maintenance and Diagnostics 95PEP Maintenance utilityThe PEP Maintenance utility displays a lis

Strany 203 - June 2007 Index

Using CallPilot system utilities Standard 1.1096 CallPilotSession TraceThe Session Trace tool displays detailed information about the activity in a us

Strany 204 - 204 CallPilot

June 2007 Using CallPilot system utilities1005r Server Maintenance and Diagnostics 97To find a session1 From the Session Type list, choose the type of

Strany 205

Using CallPilot system utilities Standard 1.1098 CallPilotResult: The session type information appears at the bottom of the window. The following exam

Strany 206 - June 2007

June 2007 Using CallPilot system utilities1005r Server Maintenance and Diagnostics 99CallPilot System MonitorThe System Monitor consists of three tabs

Komentáře k této Příručce

Žádné komentáře