650 Chapter 12 Configuring SNMP
320818-A
Depending on the type of monitor selected, the fields displayed on the
Configuration tab will change. For descriptions of the displayed fields, refer to the
appropriate section:
“Boolean monitors” on page 650
“Threshold monitors” on page 652
“Existence monitors” on page 654
Removing monitor events
To delete a monitor event, perform the following steps:
1 Select the System > Administrative > SNMP > Event > Monitor Table tab.
The Monitor Table appears (see Figure 188).
2 Select the monitor event to be removed from the Monitor Table.
3 Click Delete.
A confirmation dialog box appears.
4 Click Yes.
5 Click Apply on the toolbar to send the current changes to the Nortel
SNAS 4050. Click Commit on the toolbar to save the changes permanently.
Boolean monitors
Boolean monitors check the value of a monitored OID against a specific value,
and trigger an event if the result matches the desired operation.